Description
MAXIMUM-M30 - Automatic, hydraulic, certified, anti-terrorism bollard, able to withstand an impact with a vehicle of 7500 kg launched at speed 48 km/h
• Dynamic vehicle penetration: -0.8 m
• The emergency function E.F.O. (Emergency Fast Operation) is available upon request and allows a fast raising in 1.5 seconds
• Cylinder with built-in LED lights, the control unit can manage 2 bollards at the same time
• Foundation box complying with the EN124 (40T) regulation and independent hydraulic pump for each bollard, laterally positioned in order to avoid any damage in the event of an impact and facilitate the maintenance
• In the event of a power failure, the bollard will remain in the raised position (manual release)
• Heating for the foundation box and buzzer available as accessories
• SUGGESTED USE IN: Company or factory access driveways | Embassies | Police stations | Military bases | Ministerial buildings | Sensitive sites
Cylinder height |
900 mm |
Cylinder diameter |
275 mm |
Raising time |
4.5 s |
Lowering time |
4.5 s |
Power Supply |
230 Vac - 50/60 Hz (control panel with different voltages available on request) |
Power consumption |
1,000 W |
Hydraulic pump |
Built-in |
Load index (EN124) |
D400 (40 tonnes) |
Manual lowering cycle in case of power failure |
Manual release under the box cover |
Emergency fast operation (E.F.O.) |
Optional |
Emergency rising time |
1.5 s |
Capacitor |
31.5 μF |
Daily cycles |
3,500 |
MCBF |
3,000,000 |
Certifications |
IWA 14-1:2013 V/7200 [N3C] /48/90: -0.8 | PAS68:2013 V/7500 [N3] /48/90: -0.5 | ASTM F2656 Rating C730/7200 - P1 |
Impact resistance |
250,000 J |
Breakout resistance |
850,000 J |
Operating temperature |
-40°C ÷ +60°C [GL.HEAT available as option for temperatures lower than -10°] |
Protection level |
IP67 |
Weight (without foundation box) |
340 kg (350 kg MAX M30-I)
|